Vertiv Liebert GXT MT+EX 3KVA Online UPS

Key Features of Liebert GXT MT+EX 3KVA:
Model: Liebert GXT MT+EX
Ratings (KVA): 3 kVA
Nominal Voltage: 230 Vac
Battery capacity: 12 V/9 Ah
Warranty: 1 Year (UPS), 6 Months (Battery)

CALL FOR DETAILS: 01958510719, 01969633055

Vertiv Liebert GXT MT+EX 3KVA Online UPS
৳85,000.00
Specification:
Key Features
attr - Key Feature 1 > Model: Liebert GXT MT+EX
attr -Key Feature 2 > Ratings (KVA): 3 kVA
attr -Key Feature 3 > Nominal Voltage: 230 Vac
attr -Key Feature 4 > Battery capacity: 12 V/9 Ah
attr -Key Feature 5 > Warranty: 1 Year (UPS), 6 Months (Battery)
Call Info >

CALL FOR DETAILS: 01958510719, 01969633055

Vertiv UPS
General Brand: Vertiv
Model: Liebert GXT MT+EX
Phase: 1 Phase-In/Phase-Out
Capacity: 3000 VA/2700 W
Input Nominal Voltage: 230 Vac
Low Line Transfer (Voltage Range): 180 Vac/160 Vac/140 Vac/120 Vac ± 5% (Ambient Temperature < 35 °C) (Based on load percentage 100% to 80%; 80% to 70%; 70% to 60%; 60% to 0%)
Low Line Comeback (Voltage Range): 195 Vac/175 Vac/155 Vac/145 Vac ± 5 % (Ambient Temperature < 35 °C) (Based on load percentage 100% to 80%; 80% to 70%; 70% to 60%; 60% to 0%)
High Line Transfer (Voltage Range): 300 Vac ± 5%
High Line Comeback (Voltage Range): 290 Vac ± 5%
Frequency Range: 40 Hz to 70 Hz
Power Factor: ≥ 0.99 @ 100% load
Output Nominal Voltage" 208* Vac/220 Vac/230 Vac/240 Vac
AC Voltage Regulation: ± 1%

Frequency Range (Synchronized Range): (47 Hz to 53 Hz) or (57 Hz to 63 Hz)
Frequency Range (Battery Mode): (50 Hz ± 0.25 Hz) or (60 Hz ± 0.3 Hz)
Current Crest Ratio: 3 : 1 (maximum)
Harmonic Distortion: ≤ 3 % THD (Linear Load), ≤ 6 % THD (Non-linear Load)
Transfer Time: Bypass to Inverter (Line mode): Zero
Transfer Time: Inverter to Bypass (Line mode): 4 millisecond (ms) (Typical)
Waveform (Battery Mode): Pure Sine wave
Efficiency on AC to AC mode @ 100% load: 90%
Battery Battery Type (Standard Run Model): 12 V/9 Ah
Numbers (Standard Run Model): 6
Typical Recharge Time (Standard Run Model): 4 hours recovery to 90% capacity (Typical)
Charging Current (maximum) (Standard Run Model): 1.0 A
Charging Voltage (Standard Run Model): 82.1 Vdc ± 1%
Battery Type (Long Run Model): Depending on the capacity of external batteries
Numbers (Long Run Model): 6
Charging Current (Long Run Model): 1.0 A/2.0 A/4.0 A/6.0 A (6.0 A by default)
Float Charging Voltage (Long Run Model): 82.1 Vdc ± 1%
Indicators LCD: Panel UPS status, load level, battery level, input/output voltage, discharge timer, and fault conditions
Alarm Battery Mode: Sounding every 4 seconds
Low Battery: Sounding every second
Overload: Sounding twice every second
Fault: Continuously sounding
Physical (Standard Run Model) Dimension, D x W x H (mm): 421 x 190 x 318
(Standard Run Model) Net Weight (kg): 27.6
(Long Run Model) Dimension, D x W x H (mm): 397 x 145 x 220
(Long Run Model) Net Weight (kg): 7.4
Environment Operation Humidity and Temperature: 20% to 90% RH @ 0 °C to 50 °C** (non-condensing)
Noise Level: Less than 50 dBA @ 1 meter (m)
Management Smart RS232/USB: Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
Optional SNMP: Power management from SNMP manager and web browser
Warranty 1 Year (UPS), 6 Months (Battery)